EDS-305-M12 Series
Technical Specifications
Technical Specifications
Standards
| IEEE 802.3, 802.3u, 802.3x Processing: Store and Forward, IEEE 802.3x Full Duplex, Non-blocking Flow Control Interfaces M12 Ports: 10/100BaseT(X) Auto-Negotiation, Full/Half Duplex and MDI/MDI-X Auto-crossover |
LED Indicators
| Power, LNK/ACT Power Input Voltage: 12 to 45 VDC, 18 to 30 VAC (47 to 63 Hz) Input Current: 0.13A @ 24 VDC, 0.28A @ 24 VAC Connection: One M12 Socket (A-coding), Isolated Power Input Overload Current Protection/Limit: 1.1A Reverse Polarity Protection: Provided |
Mechanical Characteristics
| Housing | IP67 Protection, Plastic Housing Dimensions (W x H x D): 124.9 x 59.9 x 29.6 mm (4.92 x 2.36 x 1.17 in.) Weight: 250 g Mounting: Outdoor Installation Environmental Parameters Operating Temperature: 0 to 60 ยฐC (32 to 140 ยฐF), -40 to 75 ยฐC (-40 to 167 ยฐF) (Wide Temp Model) Storage Temperature: -40 to 85 ยฐC (-40 to 185 ยฐF) Relative Humidity: 5 to 95% (Non-condensing) Safety Approvals Safety: UL508 (Pending) Hazardous Environments: UL/cUL Class I, Division 2, Groups A and D |
|---|---|
| ATEX Zone 2, EEx nC IIC (Pending) Marine | GL, DNV (Pending) EMI: FCC Part 15, CISPR (EN55022) Class A EMS: EN61000-4-2 (ESD) Level 3, EN61000-4-3 (RS) Level 3, EN61000-4-4 (EFT) Level 3, EN61000-4-5 (Surge) Level 3, EN61000-4-6 (CS) Level 2, EN61000-4-8, EN61000-4-11 Shock: IEC60068-2-27 Freefall: IEC60068-2-32 |
Software, Firmware & Drivers
| File Name | Type | Version | Operating System | Release Date |
|---|---|---|---|---|
| EDS-305-M12-series-firmware-v4.1.rom | Firmware | v4.1 | โ | 2024-06-26 |
| EDS-305-M12-series-mib-package-v4.1.zip | Software Package | v4.1 | โ | 2024-06-26 |
| EDS-305-M12-series-eds-package-v1.0.zip | Software Package | v1.0 | โ | 2024-04-24 |
Support Documents
| File Name | Type | Version | Release Date |
|---|
Related Content
๐
Application Guide
Building future-proof industrial network infrastructure
๐ฅ
Video
Witness the evolution of industrial networking with Moxa
๐
Application Note
Enhance network performance for IP surveillance systems
๐
Solution Brief
Strengthen network resilience for industrial control systems
Need Help Choosing the Right Product?
Contact our engineering team for detailed specifications, pricing, and availability.