Homeโ€บ Products โ€บRTU & Remote I/O โ€บioLogik E2214

ioLogik E2214

Digital Input Input Channels: 6 Sensor Types: NPN, PNP and dry contact I/O Mode: DI or counter (up to 900 Hz) Dry Contact: Logic 0: short to GND; Logic 1: open Wet Contact: Logic 0: 0 ~ 3 VDC; Logic 1: 10 ~ 30 VDC Common Type: 6 points / 2 COM Isolation: 2 K VDC or 3 K Vrms Counter Frequency: 900 Hz Digital Filter Interval: 10 ms Overvoltage Protection: +36 VDC Store Relay Count: Yes Digital Output 6 channels, 5 A, Form A relay (normally open) Relay Specifications: Contact Rating: 5 A @ 30 VDC, 5 A @ 240 VAC, 5 A @ 110 VAC Inductive Load: 2 A Resistive Load: 5 A Dielectric Strength: 500 VAC Relay Close/Open Time: 10 ms, 5 ms (max) Insulation Resistance: 1 G min. @ 500 VDC Life: 100,000 cycles (typical) Contact Resistance: 30 m Ohm (max) Pulse Output: 20 pulses/min (resistive load) Isolation: 3 K VDC or 2 K Vrms LAN Ethernet: 10/100 Mbps, RJ45 Protection: 1.5 KV magnetic isolation Protocol: Modbus/TCP, TCP/IP, UDP, DHCP, Bootp, SNMP (MIB for I/O and Network), HTTP, SNTP

ioLogik E2214

Digital Input Input Channels: 6 Sensor Types: NPN, PNP and dry contact I/O Mode: DI or counter (up to 900 Hz) Dry Contact: Logic 0: short to GND; Logic 1: open Wet Contact: Logic 0: 0 ~ 3 VDC; Logic 1: 10 ~ 30 VDC Common Type: 6 points / 2 COM Isolation: 2 K VDC or 3 K Vrms Counter Frequency: 900 Hz Digital Filter Interval: 10 ms Overvoltage Protection: +36 VDC Store Relay Count: Yes Digital Output 6 channels, 5 A, Form A relay (normally open) Relay Specifications: Contact Rating: 5 A @ 30 VDC, 5 A @ 240 VAC, 5 A @ 110 VAC Inductive Load: 2 A Resistive Load: 5 A Dielectric Strength: 500 VAC Relay Close/Open Time: 10 ms, 5 ms (max) Insulation Resistance: 1 G min. @ 500 VDC Life: 100,000 cycles (typical) Contact Resistance: 30 m Ohm (max) Pulse Output: 20 pulses/min (resistive load) Isolation: 3 K VDC or 2 K Vrms LAN Ethernet: 10/100 Mbps, RJ45 Protection: 1.5 KV magnetic isolation Protocol: Modbus/TCP, TCP/IP, UDP, DHCP, Bootp, SNMP (MIB for I/O and Network), HTTP, SNTP

Serial Interface

RS-485 (2-wire): Data+, Data-, GND Protection: 15 KV ESD full signal protection Serial Communication Parameters Parity: None Data Bits: 8 Stop Bits: 1 Flow Control: None Speed: 1200 bps ~ 115200 bps Protocol: Modbus/RTU

Power Requirements

Input Voltage24 VDC typical, 12 ~ 48 VDC Field Power: 24 VDC typical, up to 30 VDC Mechanical Wiring: I/O cable max. 14 AWG

Operating Environment

Operating Temperature-10 ~ 60 ยฐC (14 ~ 140 ยฐF) Operating Humidity: 5 ~ 95% RH Storage Temperature: -40 ~ 85 ยฐC (-40 ~ 185 ยฐF) Storage Humidity: 5 ~ 95% RH

Software, Firmware & Drivers

File Name Type Version Operating System Release Date
ioLogik-series-firmware-v4.1.rom Firmware v4.1 โ€” 2024-06-26
ioLogik-series-mib-package-v4.1.zip Software Package v4.1 โ€” 2024-06-26
ioLogik-series-eds-package-v1.0.zip Software Package v1.0 โ€” 2024-04-24

Support Documents

File Name Type Version Release Date

Need Help Choosing the Right Product?

Contact our engineering team for detailed specifications, pricing, and availability.

Talk to an Engineer โ†’ ๐Ÿ“ž